Development of a lab-on-chip electrochemical biosensor for water quality analysis based on microalgal photosynthesis - Université Toulouse III - Paul Sabatier - Toulouse INP Accéder directement au contenu
Article Dans Une Revue Biosensors and Bioelectronics Année : 2016

Development of a lab-on-chip electrochemical biosensor for water quality analysis based on microalgal photosynthesis

Résumé

The present work was dedicated to the development of a lab-on-chip device for water toxicity analysis and more particularly herbicide detection in water. It consists in a portable system for on-site detection composed of three-electrode electrochemical microcells, integrated on a fluidic platform constructed on a glass substrate.The final goal is to yield a system that gives the possibility of conducting double, complementary detection: electrochemical and optical and therefore all materials used for the fabrication of the lab-on-chip platform were selected in order to obtain a device compatible with optical technology. The basic detection principle consisted in electrochemically monitoring disturbances in metabolic photosynthetic activitiesof algae induced by the presence of Diuron herbicide. Algal response, evaluated through oxygen (O 2) monitoring through photosynthesis was different for each herbicide concentration in the examined sample. A concentration-dependent inhibition effect of the herbicide on photosynthesis was demonstrated. Herbicide detection was achieved through a range (blank – 1µM Diuron herbicide solution) covering the limit of maximum acceptable concentration imposed by Canadian government (0.64 µM), using a halogen white light source for the stimulation of algal photosynthetic apparatus.Superior sensitivity results (limit of detection of around 0.1 µM) were obtained with an organic light emitting diode (OLED), having an emission spectrum adapted to algal absorption spectrum and assembled on the final system.
Fichier principal
Vignette du fichier
article-vf.pdf (756.8 Ko) Télécharger le fichier
Loading...

Dates et versions

hal-01503060 , version 1 (06-04-2017)
hal-01503060 , version 2 (14-04-2018)

Identifiants

Citer

Aliki Tsopela, Adrian Laborde, Ludovic Salvagnac, Vincent Ventalon, Eléna Bedel-Pereira, et al.. Development of a lab-on-chip electrochemical biosensor for water quality analysis based on microalgal photosynthesis. Biosensors and Bioelectronics, 2016, 79, pp.568-573. ⟨10.1016/j.bios.2015.12.050⟩. ⟨hal-01503060v2⟩
260 Consultations
756 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More