Determination of Thermal Contact Conductance in Vacuum-Bagged Thermoplastic Prepreg Stacks Using Infrared Thermography - Université Toulouse III - Paul Sabatier - Toulouse INP Accéder directement au contenu
Communication Dans Un Congrès Année : 2016

Determination of Thermal Contact Conductance in Vacuum-Bagged Thermoplastic Prepreg Stacks Using Infrared Thermography

Theo Baumard
Olivier de Almeida
Yannick Le Maoult
Fabrice Schmidt
Jérôme Bikard
  • Fonction : Auteur

Résumé

The infrared heating of a vacuum-bagged, thermoplastic prepreg stack of glass/PA66 was studied to investigate the influence of vacuum level on thermal contact resistance between plies. A higher vacuum level was shown experimentally to decrease the transverse heat transfer efficiency, indicating that considering only the effect of heat conduction at the plies interfaces is not sufficient to predict the temperature distribution. An inverse analysis was used to retrieve the contact resistance coefficients as a function of vacuum pressure.
Fichier principal
Vignette du fichier
esaform_papier_RTC_PA66_v3.pdf (685.39 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01609112 , version 1 (06-03-2019)

Identifiants

Citer

Theo Baumard, Olivier de Almeida, Gary Menary, Yannick Le Maoult, Fabrice Schmidt, et al.. Determination of Thermal Contact Conductance in Vacuum-Bagged Thermoplastic Prepreg Stacks Using Infrared Thermography. ESAFORM 2016 - PROCEEDINGS OF THE 19TH INTERNATIONAL ESAFORM CONFERENCE ON MATERIAL FORMING, Apr 2016, Nantes, France. art. 110002- 6 p., ⟨10.1063/1.4963511⟩. ⟨hal-01609112⟩
123 Consultations
425 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More