Influence of CBCT parameters on the output of an automatic edge-detection-based endodontic segmentation - Université Toulouse III - Paul Sabatier - Toulouse INP Accéder directement au contenu
Article Dans Une Revue Dentomaxillofacial Radiology Année : 2015

Influence of CBCT parameters on the output of an automatic edge-detection-based endodontic segmentation

Marie Georgelin-Gurgel
  • Fonction : Auteur
  • PersonId : 1032001
Jean-Philippe Mallet
  • Fonction : Auteur
  • PersonId : 1032004
Franck Diemer

Résumé

Objectives: To determine the optimal CBCT settings for an automatic edge-detection-based endodontic segmentation procedure by assessing the accuracy of the root canal measurements. Methods: 12 intact teeth with closed apexes were cut perpendicular to the root axis, at predetermined levels to the reference plane (the first section made before acquisition). Acquisitions of each specimen were performed with Kodak 9000 ® 3D (76 mm, 14 bits; Kodak Carestream Health, Trophy, France) by using different combinations of milliamperes and kilovolts. Three-dimensional images were displayed and root canals were segmented with the MeVisLab software (edge-detection-based method; MeVis Research, Bremen, Germany). Histological root canal sections were then digitized with a 0.5-to 1.0-mm resolution and compared with equivalent two-dimensional cone-beam reconstructions for each pair of settings using the Pearson correlation coefficient, regression analysis and Bland–Altman method for the canal area and Feret's diameter. After a ranking process, a Wilcoxon paired test was carried out to compare the pair of settings. Results: The best pair of acquisition settings was 3.2 mA/60 kV. Significant differences were found between 3.2 mA/60 kV and other settings (p , 0.05) for the root canal area and for Feret's diameter. Conclusions: The quantitative analyses of the root canal system with the edge-detection-based method could depend on acquisition parameters. Improvements in segmentation still need to be carried out to ensure the quality of the reconstructions when we have to deal with closer outlines and because of the low spatial resolution. Cite this article as: Michetti J, Georgelin-Gurgel M, Mallet J-P, Diemer F, Boulanouar K. Influence of CBCT parameters on the output of an automatic edge-detection-based endodontic segmentation.
Fichier principal
Vignette du fichier
michetti DMFR 2015.pdf (752.69 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-01790420 , version 1 (12-05-2018)

Identifiants

Citer

Jérôme Michetti, Marie Georgelin-Gurgel, Jean-Philippe Mallet, Franck Diemer, Kader Boulanouar. Influence of CBCT parameters on the output of an automatic edge-detection-based endodontic segmentation. Dentomaxillofacial Radiology, 2015, 44 (8), ⟨10.1259/dmfr.20140413⟩. ⟨hal-01790420⟩
144 Consultations
126 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More