Coupling DGT passive samplers and multi-collector ICP-MS: a new tool to measure Pb and Zn isotopes composition in dilute aqueous solutions - Université Toulouse III - Paul Sabatier - Toulouse INP Accéder directement au contenu
Article Dans Une Revue Chemical Geology Année : 2017

Coupling DGT passive samplers and multi-collector ICP-MS: a new tool to measure Pb and Zn isotopes composition in dilute aqueous solutions

Résumé

Using zinc (Zn) and lead (Pb) isotopes is a powerful tool to track metal pollution in environment. In this study we have developed the coupling between DGT passive samplers and multi-collector ICP-MS to measure Pb and Zn isotopic ratios in dilute aqueous solutions. The benefits of this coupling are multiple: the use of DGT device allows achieving an isotopic composition of natural water integrated over time and to pre-concentrate metals in situ. This development will greatly facilitate the field collection of samples and their preparations in cleanroom prior to their isotopic analyses. To test the capability of DGT samplers a series of experiments was achieved in cleanroom and in experimental pilot simulating a water flow. These tests have shown that there is no fractionation of Pb isotopes due to the use of DGT within the reported precision of MC-ICPMS measurements. For Zn, the diffusion process through a membrane, inherent to the use of DGT device, induces a fractionation between the isotopic composition obtained by the DGT and the natural composition. However, this bias can be easily corrected by using a simple relation independent of the time of exposure and the thickness of diffusion layer. The coupling DGT passive samplers and multi-collector ICP-MS is suitable to determine the Pb and Zn isotopic compositions in natural waters and offers new perspectives to track the anthropic pollutions in the hydrosphere.

Domaines

Géochimie
Fichier principal
Vignette du fichier
desaulty et al 2017.pdf (1.25 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01671744 , version 1 (22-12-2017)

Identifiants

Citer

Anne-Marie Desaulty, Merlin Méheut, Catherine Guerrot, Catherine Berho, Romain Millot. Coupling DGT passive samplers and multi-collector ICP-MS: a new tool to measure Pb and Zn isotopes composition in dilute aqueous solutions. Chemical Geology, 2017, 450, pp.122-134. ⟨10.1016/j.chemgeo.2016.12.023⟩. ⟨hal-01671744⟩
175 Consultations
222 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More